“X-10 could learn a few engineering tricks from you guys.” -- Chas Fox, Tech. Services Manager (Microsoft NSP) More Customer Comments... |
| Products | Purchase | FAQs | Support | About WGL | |
| Rain8 Manual Mode This mode would be the selection for anyone who wants total control of their irrigation schedules at their PC. A unique water conservation feature is the default or maximum run time values. In event of a lost X10 OFF command, the run time is determined by this default setting. Each zone has its own default value. The default values may be any value between 0 and 250 minutes. In most cases this value would be slightly larger than the greatest run time that would ever be considered for this particular zone. The example shown, zone 1 is set to 3 minutes because it is used in a green house, controlling a misting head that never runs longer than 2 minutes. Entering a 0 disables that particular zone. This mode lets you assign an individual X10 code to each sprinkler valve. You have the option of using any of the usual X10 house codes and either 1 - 8 or 9 - 16 unit codes. In the example shown here, sending X10 code E-1 ON will turn the zone 1 sprinkler valve on. Send it an E-1 OFF and the sprinkler valve turns off. The Rain8 is smart enough to assume that if it receives an E-2 ON it should first shut off the zone 1 valve, before starting zone 2. Only one zone can be active at a time. |
![]() |